QUALITY DATA OF CONVENTIONAL & INSULATING CASTABLES | ||||||||||
Quality | Al2O3% | Fe2O3% | CaO % | Application Temp. °C | PCE SK | BD 110°C/24hrs gm/cc | CCS 110°C/24hrs kg/cm2 | PLC % | Grading mm | Setting |
DENSE CASTABLES | ||||||||||
CAST 40/45 | 40/45 | 2.0 | 5 | 1450 | 27 | 2.00 | 250 | + 1.0 at 1400°C/2hrs | 0-5 | Hydraulic |
CAST 50 | 50 | 1.2 | 5 | 1500 | 30 | 2.10 | 400 | + 1.5 at 1500°C/3hrs | 0-5 | Hydraulic |
CAST 50A | 50 | 1.3 | 6 | 1500 | 30 | 2.10 | 400 | + 1.0 at 1500°C/2hrs | 0-5 | Hydraulic |
CAST 60 | 60 | 1.3 | 5 | 1600 | 32 | 2.30 | 500 | + 1.5 at 1550°C/3hrs | 0-5 | Hydraulic |
CAST 60A | 60 | 0.9 | 5 | 1600 | 31 | 2.30 | 450 | + 1.5 at 1550°C/3hrs | 0-5 | Hydraulic |
CAST 60C | 60 | 1 | 5 | 1600 | 31 | 2.25 | 350 | + 1.5 at 1550°C/3hrs | 0-5 | Hydraulic |
CAST 70 | 70 | 1.0 | 5 | 1650 | 35 | 2.70 | 350 | + 1.0 at 1450°C/3hrs | 0-6 | Hydraulic |
CAST 70A | 70 | 1.5 | 5.5 | 1650 | 34/35 | 2.70 | 500 | + 1.0 at 1450°C/3hrs | 0-6 | Hydraulic |
CAST 80B | 80 | 3.5 | 6.5 | 1550 | 35 | 2.80 | 400 | + 1.0 at 1450°C/3hrs | 0-6 | Hydraulic |
CAST 90 | 90 | 0.5 | 5.5 | 1750 | 36 | 2.90 | 650 | + 1.0 at 1500°C/3hrs | 0-5 | Hydraulic |
CAST 90A | 90 | 0.8 | 5.5 | 1750 | 36 | 2.80 | 550 | + 1.0 at 1500°C/3hrs | 0-5 | Hydraulic |
CAST 90B | 90 | 1.0 | 5.5 | 1750 | 36 | 2.80 | 550 | + 1.5 at 1550°C/3hrs | 0-6 | Hydraulic |
CAST 94 | 93 | 0.3 | 5 | 1800 | 37 | 2.90 | 500 | + 1.0 at 1500°C/3hrs | 0-5 | Hydraulic |
CAST 95 | 94 | 0.3 | 5.0 | 1850 | 38+ | 2.90 | 400 | + 1.5 at 1550°C/3hrs | 0-6 | Hydraulic |
CAST 97 | 97 | 0.1 | 2.5 | 1850 | 38+ | 3.00 | 550 | + 0.5 at 1550°C/3hrs | 0-6 | Hydraulic |
INSULATING CASTABLES | ||||||||||
THERMIN 1 | 36 | 3 | 6 | 1200 | - | 0.90 | 30 | + 0,6 at 1200°C/2hrs | 0-6 | Hydraulic |
THERMIN 2 | 40 | 3 | 6 | 1400 | 1.00 | 40 | + 0,6 at 1200°C/2hrs | 0-6 | Hydraulic |